FME Mixed Hospital Devices Timed Auction Updated Daily Over 350 lots - Starting 25th and Closing 30th of January 2024 (#96) 25/01/2024 11:00 PM CET - 30/01/2024 4:53 PM CET CLOSED Starts Ending from 30/01/2024 11:02 AM CET Auction Info sam View Search ▼ Items per page 102550100 Search Sort by DefaultTime LeftLot#Lot NameNewestHighest PriceLowest PriceBidsViews Filter By Categories Category match ANY of the aboveALL of the above Featured Exclude closed lots Price Lot Number Results: Viewing items 326-350 of 353. Previous|1...89101112131415|Next123456789101112131415 Lot #358 2 x EDAN iM50 Touch Screen Patient Monitors (Like New In Box) Including ECG, SpO2, NIBP, IBP1, IBP2, T1, T2 and CO2 Module Holder Options *Mfd 2020* with 2 x Batteries, 2 x BP Hoses, 2 x BP Cuff, 2 x IBP Pressure Transducers, 2 x SpO2 Sensors, 2 x CO2 Sampling Lines, 2 x AC Power Cables and 2 x Stands *Stock Photo* View details StatusUnsold Lot #359 2 x EDAN iM50 Touch Screen Patient Monitors (Like New In Box) Including ECG, SpO2, NIBP, IBP1, IBP2, T1, T2 and CO2 Module Holder Options *Mfd 2020* with 2 x Batteries, 2 x BP Hoses, 2 x BP Cuff, 2 x IBP Pressure Transducers, 2 x SpO2 Sensors, 2 x CO2 Sampling Lines, 2 x AC Power Cables and 2 x Stands *Stock Photo* View details StatusUnsold Lot #360 2 x EDAN iM50 Touch Screen Patient Monitors (Like New In Box) Including ECG, SpO2, NIBP, IBP1, IBP2, T1, T2 and CO2 Module Holder Options *Mfd 2020* with 2 x Batteries, 2 x BP Hoses, 2 x BP Cuff, 2 x IBP Pressure Transducers, 2 x SpO2 Sensors, 2 x CO2 Sampling Lines, 2 x AC Power Cables and 2 x Stands *Stock Photo* View details StatusUnsold Lot #361 Olympus Bronchoscope BF-1T180 Engineer’s report: Optical system no fault found , crushing at the Angulation level, Insertion tube plied, Light transmission no fault found, Channels no fault found, Torn distal sheath, Leak no fault found: *2445157 View details Winning BidN/A Lot #362 Olympus Gastroscope GIF-Q180 Engineer report: Optical system no fault found, Angulation no fault found, Insertion tube no fault found , Light transmission brightness issue , Channels no fault found , Leak in the handle, *2204129 View details Winning BidN/A Lot #363 Olympus Gastroscope GIF-N180 Engineer's report: Optical system no fault found ,Angulation no fault found , Insertion tube not fault, Light transmission no fault found , Channels no found , Leak no fault found *2700644 View details StatusUnsold Lot #364 Olympus Bronchoscope BF-P60 Engineer report: Optical system 7 black dots on image, Angulation no fault found, Insertion tube not fault, Light transmission no fault found , Channels no found , Leak no fault found *2902754 View details Winning BidN/A Lot #365 Fujifilm Gastroscope EG-530WR Engineer report: Optical system not fault found, Angulation no fault found, Insertion tube no fault found, bent connecting tube pinched, Light transmission default found see picture, Leak no fault found *1G361K885 View details Winning BidN/A Lot #366 Fujifilm Gastroscope EG-530WR Engineer report: Optical system no image, Angulation no fault found, Insertion tube no fault found, bent connecting tube pinched, Light transmission no image, Leak no fault found *2G361K052 View details Winning BidN/A Lot #367 Fujinon Colonoscope EC-530WM3 Engineer report: Optical system no fault found, Angulation no fault found , Insertion tube folded and bent connecting tube folded , Light transmission no fault found , Channels no fault found , Leak no fault found *1C641K027 View details Winning BidN/A Lot #368 Fujinon Colonoscope EC-250WM5 - Engineer report: Optical system no fault found, Angulation no fault found, Insertion tube folded and bent connecting tube folded, Light transmission lens with infiltration, Channels no fault found, Leak on handle *6C307A103 View details Winning BidN/A Lot #369 Fujinon Colonoscope EC-530WM3 Engineer report: Optical system no fault found, Angulation no fault found, Insertion tube no fault found, Light transmission no fault found , Channels no fault found , Leak no fault found * 1C641K205 View details StatusUnsold Lot #370 Fujinon Gastroscope EG-590WR Engineer report: Optical system no fault, Angulation system broken, Insertion tube little pinch, Light transmission no fault found , Distal sheath missing Channels no fault found, Leak check no fault found *2G348K073 View details Winning BidN/A Lot #371 2 x EDAN iM50 Touch Screen Patient Monitors (Like New In Box) Including ECG, SpO2, NIBP, IBP1, IBP2, T1, T2 and CO2 Module Holder Options *Mfd 2020* with 2 x Batteries, 2 x BP Hoses, 2 x BP Cuff, 2 x IBP Pressure Transducers, 2 x SpO2 Sensors, 2 x CO2 Sampling Lines, 2 x AC Power Cables and 2 x Stands *Stock Photo* View details Winning BidN/A Lot #372 2 x EDAN iM50 Touch Screen Patient Monitors (Like New In Box) Including ECG, SpO2, NIBP, IBP1, IBP2, T1, T2 and CO2 Module Holder Options *Mfd 2020* with 2 x Batteries, 2 x BP Hoses, 2 x BP Cuff, 2 x IBP Pressure Transducers, 2 x SpO2 Sensors, 2 x CO2 Sampling Lines, 2 x AC Power Cables and 2 x Stands *Stock Photo* View details Winning BidN/A Lot #373 2 x EDAN iM50 Touch Screen Patient Monitors (Like New In Box) Including ECG, SpO2, NIBP, IBP1, IBP2, T1, T2 and CO2 Module Holder Options *Mfd 2020* with 2 x Batteries, 2 x BP Hoses, 2 x BP Cuff, 2 x IBP Pressure Transducers, 2 x SpO2 Sensors, 2 x CO2 Sampling Lines, 2 x AC Power Cables and 2 x Stands *Stock Photo* View details StatusUnsold Lot #374 2 x EDAN iM50 Touch Screen Patient Monitors (Like New In Box) Including ECG, SpO2, NIBP, IBP1, IBP2, T1, T2 and CO2 Module Holder Options *Mfd 2020* with 2 x Batteries, 2 x BP Hoses, 2 x BP Cuff, 2 x IBP Pressure Transducers, 2 x SpO2 Sensors, 2 x CO2 Sampling Lines, 2 x AC Power Cables and 2 x Stands *Stock Photo* View details StatusUnsold Lot #375 2 x EDAN iM50 Touch Screen Patient Monitors (Like New In Box) Including ECG, SpO2, NIBP, IBP1, IBP2, T1, T2 and CO2 Module Holder Options *Mfd 2020* with 2 x Batteries, 2 x BP Hoses, 2 x BP Cuff, 2 x IBP Pressure Transducers, 2 x SpO2 Sensors, 2 x CO2 Sampling Lines, 2 x AC Power Cables and 2 x Stands *Stock Photo* View details StatusUnsold Lot #376 2 x EDAN iM50 Touch Screen Patient Monitors (Like New In Box) Including ECG, SpO2, NIBP, IBP1, IBP2, T1, T2 and CO2 Module Holder Options *Mfd 2020* with 2 x Batteries, 2 x BP Hoses, 2 x BP Cuff, 2 x IBP Pressure Transducers, 2 x SpO2 Sensors, 2 x CO2 Sampling Lines, 2 x AC Power Cables and 2 x Stands *Stock Photo* View details StatusUnsold Lot #377 2 x EDAN iM50 Touch Screen Patient Monitors (Like New In Box) Including ECG, SpO2, NIBP, IBP1, IBP2, T1, T2 and CO2 Module Holder Options *Mfd 2020* with 2 x Batteries, 2 x BP Hoses, 2 x BP Cuff, 2 x IBP Pressure Transducers, 2 x SpO2 Sensors, 2 x CO2 Sampling Lines, 2 x AC Power Cables and 2 x Stands *Stock Photo* View details StatusUnsold Lot #378 2 x EDAN iM50 Touch Screen Patient Monitors (Like New In Box) Including ECG, SpO2, NIBP, IBP1, IBP2, T1, T2 and CO2 Module Holder Options *Mfd 2020* with 2 x Batteries, 2 x BP Hoses, 2 x BP Cuff, 2 x IBP Pressure Transducers, 2 x SpO2 Sensors, 2 x CO2 Sampling Lines, 2 x AC Power Cables and 2 x Stands *Stock Photo* View details StatusUnsold Lot #379 2 x EDAN iM50 Touch Screen Patient Monitors (Like New In Box) Including ECG, SpO2, NIBP, IBP1, IBP2, T1, T2 and CO2 Module Holder Options *Mfd 2020* with 2 x Batteries, 2 x BP Hoses, 2 x BP Cuff, 2 x IBP Pressure Transducers, 2 x SpO2 Sensors, 2 x CO2 Sampling Lines, 2 x AC Power Cables and 2 x Stands *Stock Photo* View details StatusUnsold Lot #380 2 x EDAN iM50 Touch Screen Patient Monitors (Like New In Box) Including ECG, SpO2, NIBP, IBP1, IBP2, T1, T2 and CO2 Module Holder Options *Mfd 2020* with 2 x Batteries, 2 x BP Hoses, 2 x BP Cuff, 2 x IBP Pressure Transducers, 2 x SpO2 Sensors, 2 x CO2 Sampling Lines, 2 x AC Power Cables and 2 x Stands *Stock Photo* View details StatusUnsold Lot #381 GE Ultrasound Voluson S8 - YOM 02/2014 - S/W 12.0.3.151 - Options - 3D/4D - SonoNT - DICOM - BT Activation w/ GE Probe C1-5-RS - YOM 06-2019 and Sony Digital Graphic Printer UP-D897 (Powers up) *244566SU6/781542WX6* View details StatusUnsold Lot #382 Fujifilm Gastroscope EG-530WR Engineer report: Optical system not fault found, Angulation no fault found, Insertion tube and bent connecting tube pinched, Light transmission no default found, leak no fault found *2G361K896 View details Winning BidN/A Items per page 102550100 Previous|1...89101112131415|Next123456789101112131415 Previous 123456789101112131415 Next Previous 123456789101112131415 Next